Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools. Pool and equipment are about six years old. It seems to be the gas valve. When I try to start it now, the sequence goes like this: 1. After a minute or so, it says "Ign Fault". I usually check these by disconnecting all power to the unit and then use my screwdriver to see if I can manually turn the fan blades.
Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools, Jandy Heater - Check IGN Steps @ 82-85 degrees. JavaScript is disabled. By detecting back pressure inside the heat exchanger, this control determines whether or not water is available to the heater. The only thing I have not done after reading some posts here, is to inspect the flame sensor wiring. So I opened up our Jandy Legacy LRZ 399,000 to replace the insulation panels. I have a jandy LXI 400p.
My heater is giving me a code after about one minute of heating up. I still think you should rule out gas supply issues before you go any further. You need to figure out which of these possible things are wrong with the blower. No failures in a little over 1 year so far. The action you just performed triggered the security solution. Hello , This is an inactive thread.
I am getting the following fault code on my Zodiac Electronic If this doesn't work then you should look at the red light on the top side of the grey fenwal ignition module (as shown in photo below) blinks and count the number of times it blinks. You must log in or register to reply here. If you are not getting the exhaust motor to blow then check it.it could be seized. Therefore, if the blower isn't even coming on (1st step), the problem is with the blower, right? The flame sensor is used as protection against gas leaks. I am having the same problem. You must log in or register to reply here. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools, Jandy Lxi 250 Heater - Fault Check Ign Control. Power cycle the heater to clear the code, try it again the next day- same thing, 65 degrees to 84 totally fine then the error. Getting an "CHECK IGN STEPS" failure code on a Jandy JXi heater. I know you've reported it doesn't light at all but please check again. We had this issue with our Jandy heater. You could also try using a steel or brass brush to clean the burners. The diagnostic light does not come on.During this process, there is no heat generated at allit doesn't fire. Gas leaks can be very dangerous and lethal. To connect the hose to the bib, turn it clockwise. TESTED FOR SUFFICIENT GAS 7.5 SUPPLY 2.5 MANIFOLD. Looking for a Jandy tech in the Western PA (Pittsburgh) area that might be able to help? I decided to get out and turned it off. I have a Jandy JXI400 heater. If needed, simply add enough water to your pool to reach the proper levels, and your surge or pump pulsing problem should be resolved in no time. Original installer (2 years old) won't return calls and no one else will touch his work. When the burners ignite, raise the thermostat and examine the reading. We turned it on and tested it after it was installed and it worked great. Water Connections. Let's take it step by step STEP 1: TRANSFORMER CHECK If your heater has no power at all, check the circuit breaker or look for a popped GFCI outlet.
Getting a Fault Check Versaflo when trying to fire up jandy Display as a link instead, But I have gas to the valve, I have checked voltage and resistance everywhere, and its all in range. I have Jandy LRZ Legacy Natural gas heater. In my case it was the sensor connections on the sensor mounted close to the blower motor that has a soft rubber hose connecting tube. February 18, 2011 in All Swimming Pools Types. Fan starts running and cool air starts blowing from the top of the unit, and continues to blow until it shuts down2. It may not display this or other websites correctly. I now keep 2 spares. The air/gas mixture in the combustion chamber is immediately ignited by the hot surface igniter. Clogged Pool Filter 2. Connect the sensor terminal to the other meter probe. Vocational, Technical or Tra. This was done for safety and to be sure wires didn't accidentally come loose and short out which could short out electrical components. Apparently the bracket that holds it rusted and broke in half. No visible evidence of damage on ignitor surface (some high temperature discoloring but no white corrosion or evidence of a crack). Also, replace any damaged or cracked fittings leading into the pump. Heres how. You think? I tried to fire it up last weekend and it Ask an Expert Home Improvement Questions Pool And Spa Repair Question Summary Answer Summary Gaztech1 here, just signed in, 9H00 am eastern time in CANADA.good morning..I am ready to assist you with your issue. You must log in or register to reply here. You will have to replace it. I hear a click after about a minute, two minutes, and three minutes. Also, the 5 wires going to the blower are all thick wires in a molex type of plug. If your PB has warranted equipment for 5 years I'd call him first. It's funny cuz the blower makes it sound like the heater is working, but alas it's just my shop-vac moving the same air in that chamber. It will run up from 65-80's with no problem then throws the error consistently at that point. I am having the exact same problem ipvfletch. I saw the spa hit 100 deg and got my suit on. anything may be missing? Mike Sc Plus to be sure I didn't have the problem on other connections I did this to all other connections. Jandy JXi 400 Pdf User Manuals. If your blower is running, igniter glowing, and you hear a gas valve click this means all the safety devices are in "safe" condition and the fenwal has called for gas valve to open. During this process, there is no heat generated at allit doesn't fire. TRIED REPLACING FLAME SENSE ROD, SAME THING. Never had a new heater with clogged jets, but i guess anything is possible while the heater is waiting in distribution. Go figure!! That is because you need adequate airflow for ignition. FYI some of the most frustrating problems with heaters when you can't find a bad part is those clogged orifices. Did you remove the switch and blow out the sense lines (tubing) and try to drain anything I that may be in the case out? I had the heat and air guy come out and he found the inlet and outlet for gas and the numbers were fine. Carefully open the lid as the while you are going through the ignition sequence. By All Right Reserved by HeaterFixLab. It's just now 3 years old. Please consider. Check to see if the fan is operating. Pasted as rich text. Pool and equipment are about six years old. The heater will turn on if the pump is running when the water temperature falls below the set point. WISH I COULD FIND A COMPETENT SERVICE CO. THAT KNOWS WHAT THEY ARE DOING SO I COULD WORK ON CARS INSTEAD OF MY POOL HEATER. Trees or other objects that would restrict unobstructed air passage to and from the vent terminal should be far away from the vent aperture. Gaztech1.
How to repair jandy lrz fault check ignition. For 2 day - YouTube The table below shows the required gas supply pressure. There can be several reasons why your Jandy pool heater wont ignite. In order to see it properly you need to release that panel and swing it out if you have not done this yet. Faulty Pilot 7. I keep reading the intake is on the bottom of the heater, but then there's this air pressure slider on the side which is adjustable. Amazing, we also had the ignition issue, haven't used the lxi400 for 2 seasons. I see some leaves in there, but nothing crazy. Oh, and gas valves very rarely go bad. Im not sure which screws to take off to give me access to the control panel raceway. David is a man who loves doing research and finding out the best solution to any type of heating appliance issues like heaters and fireplaces. cycles through this 3 times them displays the ags error. Call for service if the heat pump is still not working. You can call Jandy customer care Monday through Friday, 8 AM-5 PM (PST) on this number- 800.822.7933 or send an email to the following address-
[email protected]. Drain the water into the grass. JXi Heater - how do I check to see if the air flow sensor is working right, Check Valve between spa and pool return leak, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Air In Gas Line FAQs: Why is my Jandy heater not working? If it does you don't need to replace the igniter. I've checked the igniter and it seems fine. Subsequent nights it would cut out with CHECK FLOW. This could void the warranty so I'd check first.
Sounds like the place that installed isn't a warranty station. I read through the manual and found the whole ignition process (something like pre-blower, check air pressure sensor to let blower keep going, 15 second purge, then igniter gets warmed up, then gas, lastly flame sensor lets it stay on or kills the gas). You are using an out of date browser. I don't know how to further disassemble my heater to get to where the actual blower is mounted. You can stop after draining the tank until clean water starts to come out and there is no sputtering. JavaScript is disabled. Look at the top or side of the gas valve for the two wires attached to the solenoid terminals. Malfunctioning Of The Valves FAQ: What does the FLO error code mean on the pool heater? Upload or insert images from URL. So you disconnect the wire from the air flow switch and put it back on and the units fires up OK? JavaScript is disabled. Not solid either. It is easy to do. Clear editor. Your link has been automatically embedded. I still am not getting any blinking at the LED on the panel. Section 11. I will need to rig up some kind of coat hanger or something to pull out some of that debris under there. Check the gas supply to make sure it matches the gas specified on the heaters rating plate. One other thing to mention is that I noticed what appear to be dried mouse droppings inside the heater. Any thoughts or suggestions appreciated as I wait for the gas company to install a new meter in about 3 weeks.. which I do not really expect to solve the problem. Home Jandy JXi/LXi Ignition Control Kit | R0456900 Ignition Control For Use With: Model 200, 260, 400 JXi and LXi Low NOx Heaters; Natural & Propane Gas.
Jandy pool heater lxi model says check ignition fault what I removed the front panel and I see the wiring and boards in there. Check to see if your weirs hinges are still working properly and repair any damaged or jammed doors. I am having the same problem,Unit is 1 yr old. Also, there should be a debris trap close to the heater. 1.8K views, 9 likes, 1 loves, 0 comments, 0 shares, Facebook Watch Videos from Pool Specialists: we just uploaded another informative video to our. Seemed to fire up normally, whoosh and heat blowing etc. Disabled Safety Switches 6. You are using an out of date browser. $20 OFF Chlorine Flash Sale.
You cannot paste images directly. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. FREE SHIPPING on Orders $50+. It's been months since we turned it on but today we tried turning it on and. Will have to verify what I blew out cleaned out underneath good. Youll notice a side with different terminals when you turn the pressure switch around. Let's look at various approaches to fix faulty combustion. Our installer could not find anything wrong with the unit, so he surmised it was caused by insufficient gas pressure. It's amazing how often somebody simply shut a valve. On there is another Y/BK wire which goes to the air flow switch. Little over 4 years old. PB is coming out again to check. Yes, exactly and it fires up normally after that. Make a note of where the wires join the valve so you can reconnect them later. Natural gas is bone dry.
Jandy JXI "CHECK IGN STEPS"? - Trouble Free Pool If the igniter doesn't glow, check the safety circuits, i.e.
Jandy Lxi 250 Heater - Fault Check Ign Control - Pool and Spa Forum